| 4 Spotmeters |
4 Areas (Box, max/min/average/position) |
Isotherm (above, below, interval) |
Reference temperature |
Temperature Difference (between measurement functions Reference temperature) |
Measurement Mask Filter |
Schedule response File sending (ftp) email (SMTP) |
Measurement corrections Global and individual object parameters |
6 automatic alarms on any selected measurement function, Digital In, Camera temperature function |
Response Digital Out, log, store image, file sending (ftp), email (SMTP), notification |
Ethernet, purpose Control, result and image |
Ethernet, type 100 Mbps |
Ethernet, standard IEEE 802.3 |
Ethernet, connector type RJ-45 |
Ethernet, communication TCP/IP socket-based FLIR proprietary |
Ethernet, video streaming MPEG-4, ISO/IEC 14496-1 MPEG-4 ASP@L5 |
Ethernet, power Power over Ethernet, PoE IEEE 802.3af class 0 |
Ethernet, image streaming 16-bit 320 x 240 pixels |
- Signal linear |
- Temperature linear |
- Radiometric |
Ethernet, protocols TCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, ftp, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour), uPnP |
Digital input 2 opto-isolated, 10-30 VDC |
Digital input, purpose Image tag (start/stop/general), Input ext. Device (programmatically read) |
Digital output 2 opto-isolated, 10-30 VDC, max 100 mA |
Digital output, purpose As function of alarm, output to ext. Device (programmatically set) |
Digital I/O, isolation voltage 500 VRMS |
Digital I/O, supply voltage 12/24 VDC, max 200 mA |
Digital I/O, connector type 6-pole jackable screw terminal |
Video, purpose Composite video output, PAL and NTSC compatible |
Video, connector type Standard BNC connector |
Field of view (FOV) 25° x 19° |
Close focus limit 0.4 m (1.31 ft.) |
Focal length 18 mm (0.7 in.) |
Spatial resolution (IFOV) 1.36 mrad |
Lens identification Automatic |
F-number 1.3 |
Thermal sensitivity/NETD 70 mK @ +30 °C (+86 °F) |
Image frequency 30 Hz |
Focus Automatic or manual (built in motor) |
Electronic zoom 1-8x continuous, interpolating zooming on images |
Detector data |
Detector type Focal Plane Array (FPA), uncooled microbolometer |
Spectral range 7.5-13 µm |
Resolution 320 x 240 pixels |
Detector pitch 25 µm |
Detector time constant Typical 12 ms |
Object temperature range -20 °C to +120 °C (-4 °F to +248 °F) |
0 °C to +350 °C (32 °F to +662 °F) |
optional 250 °C to +1200 °C (482 °F to 2192 °F) |
Accuracy ±2 °C (±3.6 °F) or ±2% of reading |
External power operation 12/24 VDC, 24 W absolute max |
External power, connector type 2-pole jackable screw terminal |
Voltage Allowed range 10-30 VDC |
Operating temperature range -15 °C to +50 °C (+5 °F to +122 °F) |
Storage temperature range -40 °C to +70 °C (-40 °F to +158 °F) |
Humidity (operating and storage) IEC 60068-2-30/24 h 95% relative humidity +25 °C to +40 °C (+77 °F to +104 °F) |
EMC EN 61000-6-2:2001 (Immunity), EN 61000-6-3:2001 (Emission), FCC 47 CFR Part 15 Class B (Emission) |
Encapsulation IP 40 (IEC 60529) |
Bump 25 g (IEC 60068-2-29) |
Vibration 2 g (IEC 60068-2-6) |
Weight 0.7 kg (1.54 lb.) |
Camera size (L s W s H) 170 x 70 x 70 mm (6.7 x 2.8 x 2.8 in.) |
Tripod mounting UNC 1/4”-20 (on three sides) |
Base mounting 2 x M4 thread mounting holes (on three sides) |
Housing material Aluminium |